Most papers are available under the base URL (http://kmh-lanl.hansonhub.com/publications/). The abstracts are in HTML; complete papers in Portable Document Format (pdf) and some in Postscript (ps). Go to bottom of page for further information about formats. Viewgraphs are available from talks on many of these topics. Most of these articles are available at Kenneth M. Hanson on ResearchGate.
"History of proton radiography and tomography," Kenneth Hanson and Uwe Schneider, in Zeit. Med. Phys. 32, pp. 2-4 (2022), doi:10.1016/j.zemedi.2021.11.005 (abstract), (pdf, 351 KB)
"Brief photographic history of the SPIE Medical Imaging meetings," Kenneth M. Hanson, in Jour. Med. Imaging 9(S1), 012204 (2022), doi:10.1117/1.JMI.9.S1.012204, (abstract), (pdf, 19.0 MB)
"Breast ultrasound tomography with two parallel transducer arrays," Lianjie Huang, Junseob Shin, Ting Chen, Youzuo Lin, Kai Gao, Miranda Intrator, Kenneth Hanson, in Physics in Medical Imaging, Proc. SPIE 9783 (2016), (abstract), (pdf, 1370 KB)
"Breast ultrasound tomography with two parallel transducer arrays: Preliminary clinical results," Lianjie Huang, Junseob Shin, Ting Chen, Youzuo Lin, Miranda Intrator, Kenneth Hanson, Katherine Epstein, Daniel Sandoval, Michael Williamson, in Ultrasonic Imaging and Tomography, Proc. SPIE 9419 (2015), (abstract), (pdf, 1996 KB)
"Breast ultrasound waveform tomography: Using both transmission and reflection data, and numerical virtual point sources," Lianjie Huang, Youzuo Lin, Zhigang Zhang, Yassin Labyed, Sirui Tan, Nghia Nguyen, Kenneth Hanson, Daniel Sandoval, Michael Williamson, in Medical Imaging: Ultrasonic Imaging and Signal Processing, Proc. SPIE 9040 (2014), (abstract), (pdf, 1154 KB)
"Detection of breast microcalcifications with super-resolution ultrasound imaging: a clinical study," Lianjie Huang, Yassin Labyed, Kenneth Hanson, Daniel Sandoval, Jennifer Pohl, and Michael Williamson, in Proc. SPIE 8675 (2013), doi:10.1117/12.2007653 (abstract), (pdf, 1996 KB)
"History of Proton and Ion Imaging, Kenneth M Hanson, in Medical Imaging with Protons and Ions, R. W. M. Schulte and U. Schneider, eds., pp. 1-9?? (Taylor & Francis Books, Dordrecht, 2013) (abstract), (pdf, 122 KB)
"Meta-analysis options for inconsistent nuclear measurements," Tom Burr, Brian Williams, Stephen Croft, Morgan White and Ken Hanson, in Nuclear Science and Engineering 173, pp. 15-27 (2013), (abstract), (pdf, 181 KB)
"Performance-based assessment of reconstructed images," K. M. Hanson, in Medical Imaging: Image Perception, B. Sahiner and D. J. Manning, eds., Proc. SPIE 7263 (2009), doi:10.1117/12.817793, (abstract), (pdf, 684 KB)
"Ultrasound Pulse-Echo Imaging with an Optimized Propagator," Lianjie Huang, Cuiping Li, Neb Duric, Youli Quan, and Kenneth M. Hanson, in BioMedical Engineering and Informatics, pp. 281-285 (2008), doi:10.1109/BMEI.2008.289, (abstract), (pdf, 753 KB)
"Globally optimized Fourier finite-difference method for ultrasound breast imaging," L. Huang, K. M. Hanson, Y. Quan, C. Li, and N. Duric, in Medical Imaging: Ultrasonic Imaging and Signal Processing, S. A. McAleavey and J. D'hooge, eds., Proc. SPIE 6290 (2008) (abstract), (pdf, 758 KB)
"Lessons about likelihood functions from nuclear physics," K. M. Hanson, in Bayesian Inference and Maximum Entropy Methods in Science and Engineering, K. H. Knuth et al., eds., AIP Conf. Proc. 954, pp. 458-467 (AIP, Melville, 2007), doi:10.1063/1.2821298, arXiv: 0712.0021 (abstract), (pdf, 171 KB)
"Performance-based assessment of reconstructed images," K. M. Hanson, in Medical Imaging: Image Perception, B. Sahiner and D. J. Manning, eds., Proc. SPIE 7263 (2009), doi:10.1117/12.817793, (abstract), (pdf, 684 KB)
"Probing the covariance matrix ," Kenneth M. Hanson, in Bayesian Inference and Maximum Entropy Methods in Science and Engineering, A. Mohammad-Djafari, ed., AIP Conf. Proc. 872, pp. 255-263 (AIP, Melville, 2006), doi:10.1063/1.2423282, (abstract), (pdf, 527 KB)
"Combining differential and integral experiments on 239Pu for reducing uncertainties in nuclear data applications," T. Kawano, K. M. Hanson, S. C. Frankle, P. Talou, M. B. Chadwick, R. C. Little, in Nuclear Data Needs For Generation IV, pp. 138-144 (World Scientific Publishing, Singapore, 2006), doi:10.1142/9789812773401_0015, (abstract)
"Bayesian analysis of inconsistent measurements of neutron cross sections," K. M. Hanson, Bayesian Inference and Maximum Entropy Methods in Science and Engineering, K. H. Knuth, A. E. Abbas, R. D. Morris, and J. P. Castle, eds., AIP Conf. Proc. 803, pp. 431-439 (AIP, Melville, 2005), doi:10.1063/1.2149823, (abstract), (pdf, 527 KB)
"Evaluation and Propagation of the 239Pu fission cross-section uncertainties using a Monte Carlo technique," T. Kawano, K. M. Hanson, S. C. Frankle, P. Talou, M. B. Chadwick, and R. C. Little, Nucl. Sci. Eng. 153, pp. 1-7 (2006) (abstract), (pdf, 242 KB)
"Probabilistic interpretation of Peelle's pertinent puzzle and its resolution," K. M. Hanson, T. Kawano, and P. Talou, Proc. Int. Conf. Nuclear Data for Science and Technology, R.C. Haight, M.B. Chadwick, T. Kawano, and P. Talou, eds., AIP Conf. Proc. 769, pp. 304-307 (AIP, Melville, 2005) (abstract), (pdf, 245 KB)
"Hierarchical Bayesian analysis and the Preston-Tonks-Wallace model," M. Fugate, B. Williams, D. Higdon, K. M. Hanson, J. Gattiker, S.-R. Chen, C. Unal, Los Alamos Report LA-UR-05-3935 (2005) (abstract), (pdf, 3600 KB)
Sensitivity Analysis of Model Output, K. M. Hanson and F. M. Hemez, eds. (Los Alamos Research Library, 2005; LANL Library archive) (540 pages) Forward, Proceedings-alternate
"Inference about the plastic behavior of materials from experimental data," K. M. Hanson, Sensitivity Analysis of Model Output, K. M. Hanson and F. M. Hemez, eds., pp. 126-136 (Los Alamos Research Library, 2005) (abstract), (pdf, 540 KB) "Halftoning and Quasi-Monte Carlo," K. M. Hanson, Sensitivity Analysis of Model Output, K. M. Hanson and F. M. Hemez, eds., pp. 430-442 (Los Alamos Research Library, 2005) (abstract), (pdf, 573 KB) "Introduction to PTW," K. M. Hanson, Los Alamos Report LA-UR-04-0305 (2004) (pdf, 160 KB) "Quasi-Monte Carlo: halftoning in high dimensions?," K. M. Hanson, Computational Imaging, C. A. Bouman and R. L. Stevenson, eds., Proc. SPIE 5016, pp. 161-172 (2003), doi:10.1117/12.484808, (abstract), (pdf, 741 KB) "Uncertainty quantification of simulation codes based on experimental data," K. M. Hanson and F. M. Hemez, Proc. 41st AIAA Aerospace Sciences (AIAA, 2003) (abstract), (pdf, 318 KB) "Synopsis of a Workshop on Quantification of Uncertainties in Physics Simulations," K. M. Hanson, J. M. Booker, and F. M. Hemez, Los Alamos Report LA-UR-02-7331 (2002) (abstract), (pdf, 252 KB) "Use of Probability Gradients in Hybrid MCMC and a New Convergence Test," Los Alamos Report LA-UR-02-4105, summary of talk presented at 7th Valencia International Meeting on Bayesian Statistics, June 5, 2002, Tenerife, Spain (abstract), (pdf, 165 KB) "A framework for assessing confidence in computational predictions," K. M. Hanson and F. M. Hemez, Experimental Techniques 25, pp. 50-55 (Soc. Exp. Mechanics, 2001) (abstract), (pdf, 232 KB) "A modular approach to simulation with automatic sensitivity calculation," K. M. Hanson and G. S Cunningham, in Proc. Third Int. Symp. on Sensitivity Analysis of Model Output, P. Prado and R. Bolado, eds., pp. 83-86 (CIEMAT, Madrid, 2001) (abstract), (html, 50 KB), (pdf, 147 KB) "Markov Chain Monte Carlo posterior sampling with the Hamiltonian method," K. M. Hanson, Proc. Third Int. Symp. on Sensitivity Analysis of Model Output, P. Prado and R. Bolado, eds., pp. 259-262 (CIEMAT, Madrid, 2001) (abstract), (html, 30 KB), (pdf, 38 KB) "Medical Image Processing - 1984 to 1999", Selected SPIE Papers on CD-ROM, vol. 13, K. M. Hanson, ed. (SPIE, Bellingham, 2001; ISBN: 0-8194-3734-4) (summary) (Collection of 367 papers chosen from SPIE's publications from 1984 to 1999 with a 47-page introduction; approx. 4000 pages on two CD-ROMs) "Markov Chain Monte Carlo posterior sampling with the Hamiltonian method," Kenneth M. Hanson, Medical Imaging: Image Processing, M. Sonka and K. M. Hanson, eds., Proc. SPIE 4322, pp. 456-467 (2001), doi:10.1117/12.431119, (abstract), (pdf, 170 KB) Medical Imaging: Image Processing, Proc. SPIE 4322, M. Sonka and K. M. Hanson, eds. (SPIE, Bellingham, 2001) (2050 pages) "Inference from Rossi traces," Kenneth M. Hanson and Jane M. Booker, Bayesian Inference and Maximum Entropy Methods in Science and Engineering, A. Mohammad-Djafari, ed., AIP Conf. Proc. 568, pp. 604-614 (AIP, Melville, NY, 2001), doi:10.1063/1.1381921, (abstract), (pdf, 264 KB) "Bayesian background estimation," R. Fischer, V. Dose, K. M. Hanson, and W. von der Linden, Bayesian Inference and Maximum Entropy Methods in Science
and Engineering, J. T. Rychert, G. J. Erickson, and C. R. Smith, eds., AIP Conf.
Proc. 567, pp. 193-212 (Amer. Inst. Phys., Melville, NY, 2001), doi:10.1063/1.1381857,
(abstract), (pdf, 1300 KB) "Background estimation in experimental spectra," R. Fischer, K. M. Hanson, V. Dose, and W. von der Linden, Phys. Rev. E 61, pp. 1152-1161 (2000) (abstract), (preprint, pdf, 260 KB), (ps, 353 KB), (scanned from journal, pdf, 1590 KB) Medical Imaging: Image Processing, Proc. SPIE 3979, Kenneth M. Hanson, ed. (SPIE, Bellingham, 2000) (1688 pages) "A framework for assessing uncertainties in simulation predictions," Kenneth M. Hanson, Physica D 133, pp. 179-188 (1999) (abstract),
(pdf, 239 KB)
"Gradient-based iterative image reconstruction scheme for time-resolved optical tomography," A.H. Hielscher, A. Klose, and K. M. Hanson, IEEE Trans. Med. Imag. 18, pp. 262-271 (1999) (abstract), (pdf, 1658 KB) "Bayesian estimation of regularization parameters for deformable surface models,"G. S. Cunningham, A. Lehovich, and K. M. Hanson, Medical Imaging: Image Processing, K.M. Hanson, ed., Proc. SPIE 3661, pp. 562-573 (1999), doi:10.1117/12.348612, (abstract), (pdf, 246 KB) Medical Imaging: Image Processing, Proc. SPIE 3661, K. M. Hanson, ed. (SPIE, Bellingham, 1999) (1706 pages) "Operation of the Bayes Inference Engine," K. M. Hanson and G. S. Cunningham, Maximum Entropy and Bayesian Methods, W. von der Linden et al., eds., pp. 309-318 (Kluwer Academic, Dordrecht, 1999) (abstract), (pdf, 506 KB) "Uncertainties in Bayesian geometric models," K. M. Hanson, G. S. Cunningham, and R. J. McKee, Proc. IEEE Int. Conf. Image Processing (IEEE, Piscataway, 1999; CD-ROM, ISBN: 0-7803-5470-2) (abstract), (pdf, 328 KB) "Three-dimensional reconstructions from low-count SPECT data using deformable models with interior intensity variations," G. S. Cunningham and K. M. Hanson, Proc. 1999 International Meeting on Fully Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine, F. Beekman, M. Defrise, and M. Viergever, eds., pp. 21-24 (1999) (abstract), (pdf, 370 KB) "Tomographic reconstruction using 3D deformable models," X. L. Battle, G. S. Cunningham, and K. M. Hanson, Phys. Med. Biol. 43, pp. 983-990 (1998) (abstract), text (pdf, 145 KB). "Two- and three-dimensional optical tomography of finger joints for diagnostics of rheumatoid arthritis," A. D. Klose, A. H. Hielscher, K. M. Hanson, and J. Beuthan, Photon Migration in Tissues, D. A. Benaron et al., eds., Proc. SPIE 3566, pp. 151-160 (1998), doi:10.1117/12.334363, (abstract), (ps.gz, 486 KB), (pdf, 321 KB) "Tomographic imaging of biological tissue by time-resolved, model-based, iterative image reconstruction," A. H. Hielscher, A. Klose, D. M. Catarious, Jr., K. M. Hanson, Advances in Optical Imaging and Photon Migration, R. R. Alfano and J. G. Fujimoto, eds., OSA Trends in Optics and Photonics Series 21, pp. 156-161 (Optical Society of America, Washington DC, 1998) (abstract), (pdf, 357 KB) "Posterior sampling with improved efficiency," K. M. Hanson and G. S. Cunningham, Medical Imaging: Image Processing, K. M. Hanson, ed., Proc. SPIE 3338, pp. 371-382 (1998), doi:10.1117/12.310914, (abstract), (ps, 522 KB), (pdf, 183 KB) "A simplified method to estimate noise power spectra," K. M. Hanson, Medical Imaging: Physics of Medical Imaging, J. T. Dobbins III and J. M. Boone, eds., Proc. SPIE 3336, pp. 243-250 (1998), doi:10.1117/12.317023, (abstract), (pdf, 265 KB). This algorithm is available as IDL code
Medical Imaging: Image Processing, Proc. SPIE 3338, K. M. Hanson, ed. (SPIE, Bellingham, 1998) (1614 pages) "Inversion based on computational simulations" K. M. Hanson, G. S. Cunningham, and S. S. Saquib, Maximum Entropy and Bayesian Methods, G. J. Erickson, J. T. Rychert, and C. R. Smith, eds., pp. 121-135 (Kluwer Academic, Dordrecht, 1998) (abstract), (ps, 407 KB), (pdf, 229 KB) "Quantified HREM observation of the S11(113)/[1bar10] grain boundary structure in aluminum and comparison with atomistic simulation," W.E. King, G. H. Campbell, S. M. Foiles, D. Cohen, and K. M. Hanson, J. Microsc. 190, pp. 131-143 (1998) (abstract), (pdf, 1724 KB) "Adjoint differentiation of hydrodynamic codes," M. L. Rightley, R. J. Henninger, and K. M. Hanson, CNLS Research Highlights (LANL, April, 1998) (abstract), (ps, 139 KB), (pdf, 425 KB) "Three-dimensional reconstructions from low-count SPECT data using deformable models," G.S. Cunningham, K. M. Hanson, and X. L. Battle, Optics Express 2(6), pp. 227-236 (1998) (abstract), (from journal, pdf, 635 KB), (pdf, 635 KB) "Inversion based on complex computational simulations," K. M. Hanson, G. S. Cunningham, and S. S. Saquib, Proc. IEEE Nonlinear Signal and Image Processing Workshop , E. Coyle and G. Adams, eds. (IEEE, Piscataway, 1998; CD-ROM, ISBN: 0 876346 09 4) (abstract), (ps, 221 KB), (pdf, 353 KB) "Three-dimensional reconstructions from low-count SPECT data using deformable models," G.S. Cunningham, K. M. Hanson, and X. L. Battle, Conf. Record IEEE NSS - Medical Imaging Conf., O. Nalcioglu, ed., pp. 1469-1474
(IEEE, Piscataway, 1998; CD-ROM, ISBN: 0 7803 4261 5)
(abstract), (pdf, 320 KB) "Uncertainty assessment for reconstructions based on deformable models," K. M. Hanson, G. S. Cunningham, and R. J. McKee, Int. J. Imaging Syst. Technol. 8, pp. 506-512 (1997) (abstract), (ps, 217 KB), (pdf, 216 KB) "Uncertainties in tomographic reconstructions based on deformable models," K. M. Hanson, G. S. Cunningham, and R. J. McKee, Medical Imaging: Image Processing, K.M. Hanson, ed., Proc. SPIE 3034, pp. 276-289 (1997), doi:10.1117/12.274095, (abstract), (ps, 486 KB), (pdf, 228 KB) "Model-based image reconstruction from time-resolved diffusion data," S. S. Saquib, K. M. Hanson, and G. S. Cunningham, Medical Imaging: Image Processing, K.M. Hanson, ed., Proc. SPIE 3034, pp. 369-380 (1997), doi:10.1117/12.274123, (abstract), (pdf, 823 KB) "3D tomographic reconstruction using geometric models," X. L. Battle, G. S. Cunningham, and K. M. Hanson, Medical Imaging: Image Processing, K.M. Hanson, ed., Proc. SPIE 3034, pp. 346-357 (1997), doi:10.1117/12.274121, (abstract), (pdf, 456 KB) Medical Imaging: Image Processing, Proc. SPIE 3034, K. M. Hanson, ed. (SPIE, Bellingham, 1997) (1182 pages) "Uncertainty estimation in reconstructed deformable models," K. M. Hanson, G. S. Cunningham, and R. J. McKee, Maximum Entropy and Bayesian Methods, M. Sears et al., eds. pp. 41-51, (Univ. Witwatersrand, Johannesburg, South Africa, 1997) (abstract), (ps, 247 KB), (pdf, 195 KB) "Kinky tomographic reconstruction," K. M. Hanson, R. L. Bilisoly, and G. S. Cunningham, Medical Imaging: Image Processing, M.H. Loew and K.M. Hanson, eds., Proc. SPIE 2710, pp. 156-166 (1996), doi:10.1117/12.237919, (abstract), (pdf, 516 KB) "Improved convergence of gradient-based reconstructions using multiscale models," G. S. Cunningham, I. Koyfman, and K. M. Hanson, Medical Imaging: Image Processing, M.H. Loew and K.M. Hanson, eds., Proc. SPIE 2710, pp. 145-155 (1996), doi:10.1117/12.237918, (abstract), (pdf, 566 KB) "Uncertainty in tomographic reconstructions (U)," K. M. Hanson, G. S. Cunningham, and R. J. McKee, Proc. 9th Nucl. Expl. Code Devel. Conf., F. Graviana, et al., eds.
(Lawrence Livermore National Laboratory, 1996) "Application of forward and adjoint techniques to hydrocode sensitivity analysis (U),"
R. L. Henninger, P. J. Maudlin, M. L. Rightley, and K. M. Hanson, Proc. 9th Nucl. Expl. Code Devel. Conf.,
F. Graviana, et al., eds. (Lawrence Livermore National Laboratory, 1996) "Uncertainty estimation for Bayesian reconstructions from low-count SPECT data," G. S. Cunningham and K. M. Hanson, IEEE Medical Imaging Conf. (1996) (abstract), (pdf, 123 KB) "The Bayes Inference Engine," K. M. Hanson and G. S. Cunningham, Maximum Entropy and Bayesian Methods, K.M. Hanson and R.N. Silver, eds., pp. 125-134 (Kluwer Academic, Dordrecht, 1996) (abstract), (pdf, 122 KB), (ps.gz, 66 KB), (ps.Z, 92 KB) "Toward optimal observer performance of detection and discrimination tasks on reconstructions from sparse data," R.F. Wagner, K. J. Myers, M. P. Anderson, D. G. Brown, and K. M. Hanson, Maximum Entropy and Bayesian Methods, K.M. Hanson and R.N. Silver, eds., pp. 211-220 (Kluwer Academic, 1996) (abstract), (ps, 136 KB), (pdf, 139 KB) Medical Imaging: Image Processing, Proc. SPIE 2710, M. H. Loew and K. M. Hanson, eds. (SPIE, Bellingham, 1996) (1056 pages) Maximum Entropy and Bayesian Methods, K. M. Hanson and R. N. Silver, eds. (Kluwer Academic, Dordrecht, 1996) (475 pages) "Measurement of microdensitometer wobble," K. M. Hanson, Selected Papers on Microdensitometry,
R. E. Swing, ed., pp. 394-396 (SPIE, Bellingham, 1995) (reprinted from J. Imag.
Sci. 30, 274-276, 1986 (abstract), , paper (pdf, 1164 KB)) "A computational approach to Bayesian inference," K. M. Hanson and G. S. Cunningham, Computing Science and Statistics 27, M. M. Meyer and J. L. Rosenberger, eds., pp. 202-211 (Interface Foundation, Fairfax, VA 22039-7400, 1996) (abstract), (ps, 1657 KB), (pdf, 146 KB) "The hard truth," K. M. Hanson and G. S. Cunningham, Maximum Entropy and Bayesian Methods, J. Skilling and S. Sibisi, eds., pp. 157-164 (Kluwer Academic, Dordrecht, 1996) (abstract), (ps.zip 144 KB), (pdf, 91 KB) "Estimators for the Cauchy distribution," K. M. Hanson and D. R. Wolf, Maximum Entropy and Bayesian Methods, G. R. Heidbreder, ed., pp. 255-263 (Kluwer Academic, Dordrecht, 1996)
(abstract)
(pdf, 180 KB)
"Exploring the reliability of Bayesian reconstructions," K. M. Hanson and G. S. Cunningham, Medical Imaging: Image Processing, M. H. Loew, ed., Proc. SPIE 2434, pp. 416-423 (1995), doi:10.1117/12.208713 doi:10.1117/12.208713
(abstract) (ps, 437 KB), (pdf, 105 KB) "Neural network performance for binary discrimination tasks. Part II: Effect of task, training, and feature pre-selection," K.J. Myers, M. P. Anderson, D. G. Brown, R. F. Wagner, and K. M. Hanson, Medical Imaging: Image Processing, M. H. Loew, ed., Proc. SPIE 2434, pp. 828-837 (1995), doi:10.1117/12.208757, (abstract), (pdf, 105 KB) "An interactive tool for Bayesian inference," G. S. Cunningham, K. M. Hanson, G. R. Jennings, Jr., and D. R. Wolf, Review of Progress in Quantitative Nondestructive Evaluation 14A, D. O. Thompson and D. E. Chimenti, eds., pp. 747-754 (Plenum, New York, 1995) (abstract), (pdf, 265 KB) "Validation of hydrocode predictions," K. M. Hanson and G. S. Cunningham, 8th. Nucl. Expl. Code Design. Conf., E. Caramana and C. McMillan, eds., pp. 457-462, Los Alamos Report LA-12963-C; also separately as LA-UR-01-6671 (Los Alamos, 1995) (abstract), (pdf, 56 KB) "Human and quasi-Bayesian observers of images limited by quantum noise, object variability, and artifacts," K. J. Myers, R. F. Wagner, K. M. Hanson, H. H. Barrett, and J. P. Rolland, Medical Imaging: Image Perception, H. L. Kundel, ed., Proc. SPIE 2166, pp. 180-190 (1994), doi:10.1117/12.171740, (abstract), (pdf, 310 KB) "An object-oriented implementation of a graphical-programming system," G. S. Cunningham, K. M. Hanson, G. R. Jennings, Jr., and D. R. Wolf, Medical Imaging: Image Processing, M. H. Loew, ed., Proc. SPIE 2167, pp. 914-923 (1994), doi:10.1117/12.175130, (abstract), (ps, 188 KB), (pdf, 147 KB) "Tomographic reconstruction based on flexible geometric models," K. M. Hanson, G. S. Cunningham, G. R. Jennings, Jr., and D. R. Wolf, Proc. IEEE Int. Conf. Image Processing, Vol. II, pp. 145-147 (IEEE, Piscataway, 1994) (abstract), (pdf, 160 KB) "An object-oriented optimization system," G. S. Cunningham, K. M. Hanson, G. R. Jennings, Jr., and D. R. Wolf, Proc. IEEE Int. Conf. Image Processing, Vol. III, pp. 826-830 (IEEE, Piscataway, 1994) (abstract), (pdf, 166 KB) "Bayesian reconstruction based on flexible prior models," K. M. Hanson,
J. Opt. Soc. Amer. A 10, pp. 997-1004 (1993)
(abstract), (pdf, 1560 KB) "Flexible prior models in Bayesian image analysis," K. M. Hanson, Maximum Entropy and Bayesian Methods, A. Mohammad-Djafari and G. Demoment, eds., pp. 399-406 (Kluwer Academic, Dordrecht, 1993) (abstract), (pdf, 2098 KB) "Verification of part geometry by tomographic reconstruction from several radiographs," K. M. Hanson, Los Alamos Report LA-UR-93-2502 (1993). Summary of talk presented at American Nuclear Society Meeting, San Francisco, Nov. 14-19, 1993 (pdf, 94 KB) "Binary task performance on images reconstructed using MEMSYS 3: Comparison of machine and human observers," K. J. Myers, R. F. Wagner, and K. M. Hanson, Maximum Entropy and Bayesian Methods, A. Mohammad-Djafari and G. Demoment, eds., pp. 415-421 (Kluwer Academic, Dordrecht, 1993) (abstract), (pdf, 2036 KB) "Introduction to Bayesian image analysis," K. M. Hanson, Medical Imaging: Image Processing, M.H. Loew, ed., Proc. SPIE 1898, pp. 716-731 (1993), doi:10.1117/12.154577,
(abstract), (pdf, 749 KB) "Rayleigh task performance in tomographic reconstructions: Comparison of human and machine performance,"
K. J. Myers, R. F. Wagner, and K. M. Hanson, Medical
Imaging: Image Processing, M. H. Loew, ed., Proc. SPIE 1898, pp. 628-637 (1993), doi:10.1117/12.154551,
(abstract), (pdf, 1134 KB) "Tomographic reconstruction of axially symmetric objects from
a single dynamic radiograph," K. M. Hanson, Tactical Missile Warheads,
J. Carleone, ed.,
pp. 687-693 (Amer. Inst. Aeronautics and Astronautics, Washington, DC, 1993)
(abstract), (pdf, 1637 MB) "Reconstruction based on flexible prior models," K. M. Hanson, Medical Imaging: Image Processing, M.H. Loew, ed., Proc. SPIE 1652, pp. 183-191 (1992), doi:10.1117/12.59425 (abstract), (pdf, 1304 KB) "Task performance on constrained reconstructions: Human observers compared with suboptimal Bayesian performance,"
R. F. Wagner, K. J. Myers, and K. M. Hanson, Medical
Imaging: Image Processing, M. H. Loew, ed., Proc. SPIE 1652, pp. 352-362 (1992), doi:10.1117/12.59443,
(abstract), (pdf, 1538 KB) "Making binary decisions based on the posterior probability distribution associated with tomographic reconstructions," K. M. Hanson,
Maximum Entropy and Bayesian Methods,
C. R. Smith, G. J. Erickson, and P. O. Neudorfer, eds.,
pp. 313-326 (Kluwer Academic, Dordrecht, 1992)
(abstract),
(pdf, 1601 KB) "Simultaneous object estimation and image reconstruction in a Bayesian
setting," K. M. Hanson, Image Processing Algorithms and Techniques II, M. R. Civanlar, S. K. Mitra, and R. J. Moorhead, eds., Proc. SPIE 1452, pp. 180-191 (1991), doi:10.1117/12.45382,
(abstract), (pdf, 807 KB) "Task performance based on the posterior probability of maximum-entropy reconstructions with MEMSYS 3," K. J. Myers and K. M. Hanson, Medical Imaging
V: Image Physics, R. H. Schneider, ed., Proc. SPIE 1443, pp. 172-182 (1991), doi:10.1117/12.59443,
(abstract), (pdf, 1088 KB) "Performance of the Rayleigh task based on the posterior probability of tomographic reconstructions," K. M. Hanson and K. J. Myers, IEEE Medical Imaging Conf., pp. 2049-2053, (IEEE, Piscataway, 1991) (abstract) "Rayleigh task performance as a method to evaluate image reconstruction algorithms," K. M. Hanson and K. J. Myers, Maximum Entropy and Bayesian Methods, W. T. Grandy and L. H. Schick, eds., pp. 303-312 (Kluwer Academic, Dordrecht, 1991) (abstract), (pdf, 1807 KB) "Method of evaluating image-recovery algorithms based on task performance," K. M. Hanson, J. Opt. Soc. Amer. A 7, pp. 1294-1304 (1990) (abstract),
(pdf, 711 KB) "Optimization of the constrained algebraic reconstruction technique for a variety of visual tasks," K. M. Hanson,
Information Processing in Medical Imaging,
D. A. Ortendahl and J. Llacer, eds., Progress in clinical and biological research 363, pp. 45-57 (Wiley-Liss, New York, 1991)
(abstract),
(pdf, 643 KB) "Object detection and amplitude estimation based on maximum
a posteriori reconstructions," K. M. Hanson, Medical Imaging IV: Image Formation,
R. H. Schneider, ed., Proc. SPIE 1231, pp. 164-175 (1990), doi:10.1117/12.18794,
(abstract), (pdf, 654 KB) "Comparison of the algebraic reconstruction technique with the maximum entropy
reconstruction technique for a variety of detection tasks,"
K. J. Myers and K. M. Hanson,
Medical Imaging IV, R. H. Schneider, ed., Proc. SPIE 1231, pp. 176-187 (1990), doi:10.1117/12.18795,
(abstract),
(pdf, 726 KB) "Optimization for object localization of the constrained algebraic
reconstruction technique," K. M. Hanson, Medical Imaging III,
R. H. Schneider, S. J. Dwyer III, and R. G. Jost, eds.,
Proc. SPIE 1090,
pp. 146-153 (1989)
(abstract),
(pdf, 620 KB) "A Bayesian approach to nonlinear inversion: Abel inversion from x-ray data," K. M. Hanson, Transport Theory, Invariant Imbedding, and Integral Equations, Lect. Notes in Pure and Appl. Math. 115, P. Nelson, V. Faber, D. L. Seth, and A. B. White, Jr., eds., pp. 363-368 (Marcel Dekker, New York, 1989) (abstract),
(pdf, 1053 KB) "Optimization of reconstruction algorithms using Monte Carlo simulation,"
K. M. Hanson, Advanced Neutron Sources,
D. K. Hyer, ed., Amer. Inst. Phys. Conf. Ser. 97, pp. 721-734
(1989) (abstract) "POPART - Performance OPtimized Algebraic Reconstruction Technique," K. M. Hanson,
Visual Comm. and Image Processing, T. R. Hsing, ed., Proc. SPIE 1001, pp. 318-325 (1988)
(abstract), (pdf, 14 MB) "Bayesian approach to limited-angle reconstruction in computed tomography,"
K. M. Hanson and G. W. Wecksung,
Maximum Entropy and Bayesian Methods, C. R. Smith and
G. J. Erickson, eds., pp. 255-272 (Reidel, Dordrecht, 1988)
(reprint from JOSA 73, pp. 1501-1509, 1983)
(abstract),
(pdf, 3500 KB) "Method to evaluate image-recovery algorithms based on task performance," K. M. Hanson, Medical Imaging II, R. H. Schneider and S. J.
Dwyer III, eds., Proc. SPIE 914, pp. 336-343 (1988) (abstract),
(pdf, 7 MB) "Comparison of 3D tomographic algorithms for vascular reconstruction,"
A. Rougée, K. M. Hanson, and D. Saint-Felix, Medical Imaging II, R. H.
Schneider and S. J. Dwyer III, eds., Proc. SPIE 914, pp. 397-405 (1988)
(abstract), (pdf, 6 MB) "Bayesian and related methods in image reconstruction from incomplete data," K. M. Hanson, chapter in Image Recovery: Theory and Applications, H. Stark, ed., pp. 79-125 (Academic, Orlando, 1987) (abstract),
(pdf, 1515 KB) "Evaluation of image-recovery algorithms on the basis of task performance,"
K. M. Hanson, Proc. 11eme Colloque sur le Traitement du Signal et des Images (GRETSI),
M. B. Picinbono, M. P. Tournois, and M. G. Bienvenu, eds., pp. 547-550 (1987)
(abstract),
(pdf, 1229 KB) "3-D tomographic reconstruction from limited cone-beam views,"
K. M. Hanson, D. Saint-Felix, and A. Rougée,
IEEE-ASSP/EURASIP 5th Workshop on Multidimensional Signal
Processing (1987) "Effect of nonnegativity constraints on detectability," K. M. Hanson,
Dig. of Topical Meeting on Quantum-Limited Imaging and Image
Processing, pp. 142-145 (Opt. Soc. Amer., Washington DC, 1986)
(abstract)
"Measurement of microdensitometer wobble," K. M. Hanson,
J. Imag. Sci. 30, pp. 274-276 (1986)
(abstract), (pdf, 1164 KB) "Local basis-function approach to computed tomography," K. M. Hanson and G. W. Wecksung, Appl. Opt. 24, pp. 4028-4039 (1985),
doi:10.1364/AO.24.004028, 10.1364/AO.24.004028
(abstract),
(pdf, 1528 KB) "Image processing: mathematics, engineering, or art?," K. M. Hanson,
Appl. of Optical Instru. in Medicine XIII, R. H. Schneider and
S. J. Dwyer III, eds., Proc. SPIE 535, pp. 70-81 (1985)
(abstract),
(pdf, 10 MB) "Image analysis for dynamic weapons systems,"
R. L. Whitman, K. M. Hanson, and K. A. Mueller,
Los Alamos Report LA-LP-85-15 (Los Alamos Scientific
Laboratory, Los Alamos, New Mexico, 1985)
(pdf, 339 KB) "Tomographic reconstruction of axially symmetric objects from a
single radiograph," K. M. Hanson, 16th Inter. Cong. on High Speed Photography and Photonics,
M. Andre and M. Hugonschmidt, eds., Proc. SPIE 491, pp. 180-187 (1984)
(abstract), (pdf, 2278 MB) "Optimal object and edge localization in the presence of correlated
noise," K. M. Hanson, Appl. of Optical Instru. in Medicine XII, R. H. Schneider and
S. J. Dwyer III, eds., Proc. SPIE 454, pp. 9-17 (1984)
(abstract), (pdf, 925 KB) "The observer SNR penalty for reconstructions from projections,"
R. F. Wagner, D. G. Brown, A. E. Burgess, and K. M. Hanson,
Magn. Reson. Med. 1, pp. 76-77 (1984)
(abstract),
(pdf, 154 KB) "Bayesian approach to limited-angle reconstruction in
computed tomography," K. M. Hanson and G. W. Wecksung, J. Opt. Soc. Amer. 73, pp. 1501-1509 (1983)
(abstract),
(pdf, 673 KB) "Variations in task and the ideal observer," K. M. Hanson, Applic. Optical Instrument. in Medicine XI, Gary D. Fullerton, ed., Proc. SPIE 419, pp. 60-67 (1983)
(abstract),
(pdf, 323 KB) "Bayesian approach to limited-angle CT reconstruction,"
K. M. Hanson and G. W. Wecksung,
Dig. of Topical Meeting on Signal Recovery and Synthesis with Incomplete Information
and Partial Constraints, pp. FA6-1 (Opt. Soc. Amer., Washington DC, 1983)
(abstract) "Limited angle CT reconstruction using a priori information," K. M. Hanson, Proc.
Inter. Symp. Med. Imag. and Imag. Interp., pp. 527-533 (IEEE, Piscataway, 1982)
(abstract), (pdf, 10 MB) "Proton-computed tomography of human specimens,"
K. M. Hanson, J. N. Bradbury, R. A. Koeppe, R. J. Macek, D. R. Machen, R. Morgado,
M. A. Paciotti, S. A. Sandford, and V. W. Steward,
Phys. Med. Biol. 27, pp. 25-36 (1982)
(abstract), (pdf, 1002 KB) "Lateral displacement in small-angle multiple scattering,"
H. Bichsel, K. M. Hanson, and M. E. Schillaci,
Phys. Med. Biol. 27, pp. 959-961 (1982)
(pdf, 147 KB)
"The effect of noise in computed-tomographic reconstructions on
detectability," K. M. Hanson, Proc. 15th Int. Conf. on System Sciences,
B. Shriver, T. M. Walker, R. R. Grams, and R. H. Sprague, Jr., eds.,
pp. 67-76 (1982) (abstract),
(pdf, 718 KB) "CT reconstruction from limited projection angles," K. M. Hanson, Appl. of Optical Instru.
in Medicine X, J. A. Mulvaney and G. D. Fullerton, eds., Proc. SPIE 347, pp. 166-173 (1982)
(abstract),
(pdf, 8 MB) "Radiographic screen-film noise power spectrum: calibration and intercomparison,"
J. M. Sandrik, R. F. Wagner, and K. M. Hanson, Appl. Opt. 21, pp. 3597-3601 (1982)
(abstract), (pdf, 1508 KB) "Algorithm for determining the proximity distribution from dose-averaged lineal
energies," M. Zaider, D. J. Brenner, K. M. Hanson, and G. N. Minerbo,
Radiation Research 91, pp. 95-103 (1982)
(abstract), (pdf, 2690 KB) "Noise and contrast discrimination in CT," K. M. Hanson, chapter in
Radiology of the Skull and Brain, Vol. V:
Technical Aspects of Computed Tomography,
T. H. Newton and D. G. Potts,
eds., pp. 3941-3955 (C. V. Mosby, New York, 1981)
(pdf, 700 KB) "Computed tomography using proton energy loss,"
K. M. Hanson, J. N. Bradbury, T. M. Cannon, R. L. Hutson, D. B. Laubacher,
R. J. Macek, M. A. Paciotti, and C. A. Taylor,
Phys. Med. Biol. 26, pp. 965-983 (1981)
(abstract), (pdf, 1285 KB) "On the optimality of the filtered backprojection algorithm," K. M. Hanson,
J. Comput. Assist. Tomogr. 4, pp. 361-363 (1980) (abstract),
(pdf, 468 KB) "Evaluation of edge-induced streaking artifacts in CT scanners,"
W. T. Sheridan, M. R. Keller, C. M. O'Conner, R. A. Brooks, and K. M. Hanson,
Med. Phys. 7, pp. 108-111 (1980)
(abstract), (pdf, 487 KB) "Detectability in computed tomographic images," K. M. Hanson, Med. Phys. 6, pp. 441-451 (1979), doi:10.1118/1.594534,
(abstract),
(pdf, 1720 KB) "The detective quantum efficiency of CT reconstruction:
The detection of small objects," K. M. Hanson, Appl. of Optical Instru. in Medicine
VII, J. E. Gray, ed., Proc. SPIE 173, pp. 291-298 (1979) (abstract),
(pdf, 600 KB) "Proton computed tomography," K. M. Hanson, Computed Aided Tomography
and Ultrasonics in Medicine, J. Raviv, J. F. Greenleaf, and G. T.
Herman, eds., pp. 97-106 (North-Holland, Amsterdam, 1979) (abstract),
(pdf, 520 KB) "Development of a proton-radiographic system for diagnosis and
localization of soft-tissue abnormalities - final report," K. M. Hanson, Los Alamos Report LA-7107-MS
(Los Alamos Scientific Laboratory, Los Alamos, New Mexico, 1979)
(abstract),
(pdf, 465 KB) "The application of protons to computed tomography,"
K. M. Hanson, J. N. Bradbury, T. M. Cannon, R. L. Hutson, D. B. Laubacher,
R. Macek, M. A. Paciotti, and C. A. Taylor,
IEEE Trans. Nucl. Sci. NS-25, pp. 657-660 (1978)
(abstract), (pdf, 2200 KB) "The characteristics of computed-tomographic reconstruction
noise and their effect on detectability," K. M. Hanson and D. P. Boyd,
IEEE Trans. Nucl. Sci. NS-25, pp. 160-163 (1978)
(abstract),
(pdf, 2.8 MB) "Electroproduction of single pions at low epsilon and a measurement of pion form factor up to Q2 = 10 GeV2," C. J. Bebek, et al., Phy. Rev. D17, 1693-1705 (1978) (abstract), (pdf, 613 KB). "Detectability in the presence of computed-tomographic reconstruction
noise," K. M. Hanson, Appl. of Optical Instru. in Medicine VI, J. E. Gray
and W. R. Hendee, eds., Proc. SPIE 127, pp. 304-312 (1977) (abstract),
(pdf, 9.4 MB) "Electroproduction of inclusive pions at high Q2," C. J. Bebek, et al., Phy. Rev. D16, 1986-2015 (1977) (abstract), (pdf, 156 KB) (abstract), (pdf, 1608 KB). "Scalar-transverse separation of electroproduced kappa-plus lambda and kappa-plus sigma-zero final states," C. J. Bebek, et al., Phys. Rev. D15, 3082-3084 (1977) (abstract), (pdf, 208 KB). "Electroproduction of forward protons up to Q2 = 9.5 Gev2," C. J. Bebek, et al., Phys. Rev. D15, 3077-3081 (1977) (abstract), (pdf, 263 KB). "Longitudinal-transverse separation of inclusive electroproduction of pions and protons," C. J. Bebek, et al., Phys. Rev. Lett. 38, 1051-1054 (1977) (abstract), (pdf, 205 KB). "Charged-pion electroproduction from protons up to Q2 = 9.5 GeV2," C. J. Bebek, et al., Phys. Rev. Lett. 37, 1525-1528 (1976) (abstract), (pdf, 238 KB). "Scalar-transverse separation from single pi-plus electroproduction," C. J. Bebek, et al., Phys. Rev. Lett. 37, 1326-1329 (1976) (abstract), (pdf, 302 KB). "Comparison of pi-plus and pi-minus electroproduction at 0 deg. and 90 deg. center-of-mass angles," C. J. Bebek, et al., Phys. Rev. Lett. 37, 1320-1323 (1976) (abstract), (pdf, 321 KB). "Electroproduction of protons at large transverse momentum," A. Browman, et al., Phys. Rev. Lett. 37, 974-977 (1976) (abstract), (pdf, 330 KB). "Inclusive pion electroproduction at large transverse momentum," A. Browman, et al., Phys. Rev. Lett. 37, 651-655 (1976) (abstract), (pdf, 314 KB). "Search for heavy narrow resonances produced by photons with energies up to 11.8 GeV," G. Theodosiou, et al., Phys. Rev. Lett. 37, 126-129 (1976). (abstract), (pdf, 230 KB) "Inclusive and exclusive virtual photoproduction results from Cornell," K. M. Hanson, invited paper in Proc. 1975 International Symposium on Lepton and Photon Interactions at High Energies, Stanford University, Stanford Linear Accelerator, Stanford, pp. 739-780 (1975). (abstract), (pdf, 809 KB) "Photoproduction of the psi(3100) meson at 11 GeV," B. Gittelman, et al., Phys. Rev. Lett. 35, 1616-1619 (1975). (abstract), (pdf, 210 KB) "Electroproduction of single pions with large transverse momenta," A. Browman, et al., Phys. Rev. Lett. 35, 1313-1316 (1975). (abstract), (pdf, 217 KB) "Large-Angle Quasi-Elastic Electron-Deuteron Scattering," K. M. Hanson, Thesis (Harvard University, 1970), (abstract). "Decay width of the neutral pi meson," A. Browman, et al., Phys. Rev. Lett. 33, 1400-1403 (1974). (abstract), (pdf, 280 KB) "Radiative width of the eta meson," A. Browman, et al., Phys. Rev. Lett. 32, 1067-1070 (1974). (abstract), (pdf, 227 KB) "Large-angle quasi-elastic electron-deuteron scattering," K. M. Hanson, et al., Phys. Rev. D8, 753-778 (1973). (abstract), (pdf, 1408 KB) "Pi-zero photoproduction from neutrons," A. M. Osborne, et al., Phys. Rev. Lett. 29, 1621-1624 (1972). (abstract), (pdf, 294 KB) "Pi-zero photoproduction from complex nuclei," W. T. Meyer, et al., Phys. Rev. Lett. 28, 1344-1347 (1972). (abstract), (pdf, 211 KB) "Backward-angle electron-proton elastic scattering and proton electromanetic form factors," L. E. Price, et al., Phys. Rev. D4, 45-53 (1971). (abstract), (pdf, 444 KB) "Elastic electron-proton scattering cross sections measured by a coincidence technique," M. Goitein, et al., Phys. Rev. D1, 2449-2476 (1970). (abstract), (pdf, 1495 KB) "Search for violation of time-reversal invariance in inelastic e-p scattering," J. A. Appel, et al., Phys. Rev. D1, 1285-1303 (1970). (abstract), (pdf, 1254 KB) "Coincidence measurements of single-pion electroproduction near the Delta(1236) resonance," C. Mistretta, et al., Phys. Rev. 184, 1487-1507 (1969). (abstract), (pdf, 1688 KB) "Search for the electroproduction of the N*(1470) resonance from deuterium," J. L. Alberi, et al., Phys. Rev. 176, 1631-1634 (1968). (abstract), (pdf, 248 KB) "Test of time-reversal invariance in electroproduction interactions using a polarized proton target," J. R. Chen, et al., Phys. Rev. Lett. 21, 1279-1282 (1968). (abstract), (pdf, 225 KB) "Neutron form factors from quasi-elastic electron-deuteron scattering," R. J. Budnitz, et al., Phys. Rev. 173, 1357-1390 (1968). (abstract), (pdf, 2876 KB) "Angular distributions for pi-plus electro-production and the pion form factor," C. Mistretta, et al., Phys. Rev. Lett. 20, 1523-1526 (1968). (abstract), (pdf, 194 KB) "Differential cross sections for neutral-pion electroproduction near the first pion-nucleon resonance," C. Mistretta, et al., Phys. Rev. Lett. 20, 1070-1073 (1968). (abstract), (pdf, 180 KB) "Quasi-elastic electron-deuteron scattering at forward angles," R. J. Budnitz, et al., Phys. Rev. Lett. 19, 809-812 (1967). (abstract), (pdf, 186 KB) "Measurements of elastic electron-proton scattering at high momentum transfer by a coincidence method," M. Goitein, et al., Phys. Rev. Lett. 18, 1016-1018 (1967). (abstract), (pdf, 156 KB)
(Presented at Workshop on Fully 3D Image Reconstruction in Radiology and Nuclear Medicine, Nemacolin, Pennsylvania, June 25-28, 1997)
Most papers are provided in Portable Document Format (pdf), which can be read with Acrobat Reader. Unfortunately, many of the older papers had to be scanned from microfiche, and thus are quite large and of poor quality. Some of the articles are provided in Postscript (ps), a free reader for which is Ghostscript or one of its variants. The larger Postscript files may be compressed using gzip (ps.gz) provided by GNU or using UNIX "compress" (ps.Z).
For LA-UR numbers, view Page Source.
Please report trouble downloading, viewing, or printing any of these files. (Please don't forget to describe your computing environment.) To request reprints that do not appear in the above list, please contact Ken Hanson at kmh@hansonhub.com
Return to my home page